College of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Effect of Storage Heater Shape on Performance of Built -In –Storage Solar Collector Suitable for IRAQ Environmentدراسة تأثير شكل الخزان على الأداء الأمثل لمجمع شمسي خازن ملائم للبيئة العراقية184738710.33899/rengj.2012.47387ENObed Majeed AliJournal Article20120401Abstract
This research includes a theoretical and experimental study to the effect of some designing parameters on the performance of storage solar collector and to verify its suitability in the domestic uses. Two solar collectors studies , the first collector is cylindrical with 28 cm diameter and 130 height , and the second collector is cubic with dimensions 100cm x 100cm x 8cm , each one putting in a woody frame. Ordinary window glass was used as the top transparent cover for surface facing the sun. This storage collectors can be used as storage water tank to replace the ordinary tanks commonly used in Iraqi houses.
The basic parameters were investigated systematically, these included the storage tank shape of solar collector, two models were taken, the first, cylindrical tank storage collector, and the second cubical tank storage collector having equal capacity . The other parameters was studied, the effect of loading. Loading on the storage collector were carried out with three different water withdrawal patterns, continuous loading, an intermittent loading, all water withdrawal one time in the day. The results indicate that the performance of cylindrical collector was better than the cubic collector in the continuous loading and intermittent loading after 3 PM, and the performance of cubic collector was better than cylindrical collector when all water withdrawal in the day at no load conditions.
To verify the experimental test results, a numerical study was carried out using Fluent program. The natural convection phenomenon in the enclosure of the storage collector was investigated based on the method of control volume. From the Fluent results and analysis of the problem, the temperature distribution throughout the day was obtained. The Fluent results agreed well with the experimental data obtained.
Key wards: Solar Energy ,Storage Solar Collectors, Storage Tank Shape .الخلاصةيتضمن البحث دراسة عملية ونظرية لتأثير بعض المتغيرات التصميمية على أداء مجمع شمسي خازن وتحقيق ملاءمته للاستخدامات المنزلية. شملت الدراسة مجمعين شمسيين ، المجمع الشمسي الاول عبارة عن اسطوانة ذات قطر 28 cm وطول 130 cm والمجمع الشمسي الثاني عبارة عن خزان مكعب الشكل بابعاد 100cm x 100cm x 8cm ، كل منهما يوضع في هيكل خشبي مغطى بالزجاج من الجهة المقابلة للشمس ويمكن استخدام اللاقطات الشمسية المقترحة كخزان ماء بدلا من الخزانات المعتادة في البيوت العراقية. تمت دراسة تأثير المتغيرات الأساسية والتي تضمنت تغيير شكل الخزان في المجمع الشمسي ، حيث استخدم نموذجين أحداهما ذو خزان اسطواني والأخر خزان مكعب وبنفس السعة ، كما تم دراسة تأثير ثلاثة نماذج من التحميل على أداء المجمعين هما التحميل المستمر والمتقطع كل ساعة وسحب المياه مرة واحدة في اليوم. بينت النتائج إن أداء المجمع الاسطواني أفضل عند وجود تحميل للمياه من المجمع بصورة مستمرة آو متقطعة بعد الساعة الثالثة عصراً ، بينما يكون أداء المجمع المكعب أفضل في حالة سحب المياه مرة واحدة فقط وعند عدم وجود تحميل. استخدم البرنامج العددي فلونت ((Fluent لإنجاز الجزء النظري لهذه الدراسة ويعتمد هذا البرنامج على طريقة الحجوم المحددة (Finite volumes) لدراسة ظاهرة الحمل الطبيعي داخل خزين اللاقط الشمسي. ومن التحليل العددي تم حساب توزيع درجات الحرارة خلال اليوم وقد وردت النتائج النظرية بتوافق جيد مع النتائج العملية. الكلمات الدالة: الطاقة الشمسية، المجمعات الشمسية الخازنة، شكل الخزان .https://rengj.mosuljournals.com/article_47387_8a643f20d046efd68cc264ac09299db1.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Parameters Affecting the Behavior of Reinforced Concrete Wrapped With CFRP Sheetالعوامل المؤثرة على تصرف الخرسانة المسلحة المغلفة بصفائح الكاربون1264727310.33899/rengj.2012.47273ENAzad A. MohammedYassamin K. FaiudJournal Article20120401Abstract
In this paper the behaviors of strength and deformation of short reinforced concrete column specimens wrapped with CFRP were studied through testing 48 cylindrical specimens under axial loading. The role of parameters of CFRP wrap layers and arrangement, concrete strength , main steel reinforcement , lateral reinforcement and specimen slenderness ratio was studied. Results indicated that due to wrapping with CFRP layers the state of confined concrete occurs and the properties of strength and deformation are modified considerably. The ultimate load percentage was found to vary from 123% to 280% of that of unconfined specimens. The ductility of reinforced concrete specimens was found to be increased considerably as a result of wrapping. The effect of wrapping was found to be important in the case of concrete of lower strength and poorly reinforced with both main bars and lateral reinforcements. In order to obtain higher load capacity of wrapped high strength concrete it should be reinforced highly with both types of reinforcements. In general the parameters influencing the behavior reinforced concrete confined with CFRP sheets are: number of layers, replacing layers with strips, concrete compressive strength, main bars, lateral reinforcement, and specimens slenderness ratio. An analytical model was proposed for calculating ultimate load capacity and load-strain relationship for reinforced NSC and HSC confined with CFRP sheets. The predictions were found to be accurate, and the ratio of test / calculated ultimate load was found to be 1.0043 for NSC and 1.0033 for HSC.
Keywords: Axial strain, Column, Confined concrete, High strength concrete, Lateral strain, Strengthening, Wrappingالخلاصةفي البحث الحالي تم دراسة خواص المقاومة والتشوهات لنماذج من العمود الخرسانى المسلح القصير والمغلفة بصفائح الكاربون من خلال فحص 48 نموذجا تحت الحمل المركزي. تم دراسة تأثير عوامل عدد و ترتيب طبقات صفائح الكاربون, مقاومة الخرسانة, حديد التسليح الاساسي والجانبي, نسبة النحافة للنماذج. اكدت النتائج ان بسبب التغليف تم حصول حالة الحصر و تعديل خصائص المقاومة والتشوهات. أظهرت النتائج أن نسبة الحمل الاقصى تتغير من 123% الى 280%. أن مطيلية الخرسانة المسلحة قد ازدادت بشكل ملحوظ بسبب الحصر بالصفائح. أن تأثير الحصر كان مهما في النماذج قليلة المقاومة ذات تسليح اساسي وجانبي قليل. للحصول على اكبر مقاومة للحمل للخرسانة عالية المقاومة المحصورة يجب تسليحها بشكل جيد بالحديد الاساسي والجانبي. بشكل عام ترتيب العوامل المؤثرة على تصرف الخرسانة المسلحة المحصورة بصفائح الكاربون هي: عدد الطبقات, تبديل الطبقة بالشريحة, مقاومة الخرسانة, حديد التسليح الاساسي, حديد التسليح الجانبي, نسبة النحافة للنماذج. تم تقديم طريقة للثنبؤ بالحمل الافصى و علاقة الحمل- الانفعال للخرسانة المسلحة المحصورة بالياف الكاربون. وجد بان نسبة الحمل المختبرى/النظرى يساوى 1.0043للخرسانة عادية المقاومةhttps://rengj.mosuljournals.com/article_47273_140a2be8a07a705747c84ea01286b03b.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Parasitic Torques of single phase induction motors and its effect on the generated noise and vibrationالعزوم الطفيلية في المحركات الحثية أحادية الطور وتأثيرها على الضوضاء والاهتزازات الصادرة9184739010.33899/rengj.2012.47390ENOmar Sharaf AL-Deen YehyaJournal Article20120401Abstract
This Paper presents the effects of the Parasitic Torques in a single phase induction motor, on the Vibration and Noise that’s generated from choosing unsuitable value of running capacitor. In this research a computer program has been developed of the motor Sound. The sound signal is measured by using a sound level meter and then it is transmitted to the computer through a data acquisition card and then the signal has been analyzed. In addition to that the Vibration signal has been analyzed. Experimental results has been obtained in the Anechoic Chamber Laboratory, It has been found that the optimum value of the running capacitor for this induction motor was 23μf .This gives minimum Parasitic Torques whose frequency is twice the input source frequency, and therefore minimum noise and vibration caused by this Parasitic Torque has been obtained.
Key words: "Parasitic Toque for single phase induction motor"الملخصيتناول هذا البحث تأثير قيمة متسعة التشغيل على أداء المحرك الحثي أحادي الطور ذي اللفيفتين وذلك من خلال دراسة تأثير العزوم الطفيلية ذات الطبيعة النبضية المتولدة في المحرك وتأثيرها على الضوضاء والاهتزاز عند اختيار قيمة غير ملائمة لمتسعة التشغيل في المحرك الحثي أحادي الطور .تم في هذا البحث تحليل الإشارة الصوتية للمحرك وكذلك إشارة الاهتزاز وإيجاد المركبة المتولدة من العزم النبضي من تلك الإشارة الصوتية والذي تردده يكون ضعف تردد المصدر . تم تحليل هذه الإشارات حاسوبيا عن طريق اخذ الإشارة في مختبر عديم الصدى للحصول على أفضل قراءات والتخلص من الضوضاء المحيطة , وبعد اخذ عدة قيم لمتسعة التشغيل وتغيير قيمتها بدءا من الصفر ووصولا إلى 45 مايكروفاراد تم الحصول على أفضل متسعة تشغيل وهي بحدود 23 مايكروفاراد والتي تعطي اقل عزم نبضي ضار واقل اهتزازا وضوضاء وكذلك تأكيد للنتائج التي تم الحصول عليها في بحث سابق والتي تم إثبات هذه القيمة من المتسعة للحصول على أفضل قيمة من الكفاءة وعامل القدرة والعزم والقدرة الخارجة من المحرك .الكلمات المفتاحية :"العزوم الطفيلية في المحرك الحثي أحادي الطور"https://rengj.mosuljournals.com/article_47390_b380a68dc745c51b25ff7a8654b602b2.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Effect of Drain Spacing on Water Table Depth and Soil Salinityتأثير المسافة بين المبازل على ارتفاع الماء الارضي وملوحة التربة19324739310.33899/rengj.2012.47393ENEntesar M.GhazalJournal Article20120401A computer model was made to find drain spacing with Hooghout equation then SALTMOD was applied for water and salt balances of four different soils. Crop rotation with alfalfa in 50% of the land as continuous crop(in winter and summer) and 50% of the land wheat in winter then maize in summer season.
Drain spacing can be increased than that calculated with Hooghout equation according to soil type and critical water table depth, So salinity, and water table depth were increased without exceeding root zone depth, in clay loam soil. Whereas it's increase has little effect on loamy sand soil, therefore, the best drain spacing can be chosen according to acceptable salinity in the soil .
SALTMOD gives, depending on cumulative Gumbel distribution, a reasonable indication of the predicted change in soil salinity. Under the proposed conditions of irrigation and drainage after, 10 years , the root zone salinity in 80% of area irrigated with 0.5 ds/m water, was predicted to increase in summer to ,9.46, 8,7.53, 4.3 ds/m in the clay loam, loam, sandy loam, loamy sand soil respectively.
Keywords :SALTMOD , root zone salinity ,water table depth.ملخص تم صياغة أنموذج حاسوبي لإيجاد المسافة بين المبازل من معادلة هوغاوت ثم استخدام SALTMOD لتطبيق الموازنة المائية والملحية على أربعة أنواع من الترب. تم تحديد خطة زراعية وذلك بزراعة 50% من الأرض جت كمحصول مستمر( شتوي و صيفي) و 50% من الارض حنطة كمحصول شتوي ثم ذرة كمحصول صيفي. يمكن زيادة المسافة بين المبازل عن تلك المحسوبة بمعادلة هوغاوت اعتمادا على نوع التربة وتغير العمق الحرج للماء الأرضي، ويؤدي ذلك إلى زيادة الأملاح ، وزيادة ارتفاع الماء الأرضي بدون تجاوز عمق المنطقة الجذرية في التربة المزيجية الطينية. بينما تأثيره قليل على التربة الرملية المزيجية. وبذلك يمكن اختيار أفضل مسافة بين المبازل حسب الملوحة المسموح بها في التربة . يقدم أنموذجSALTMOD ، اعتمادا على توزيع جمبل المتراكم، مؤشرا على التغير المتوقع في ملوحة التربة . تحت ظروف الري والبزل المقترحة وبعد 10 سنوات ، من المتوقع ان تصل الملوحة في 80% من الارض المروية بمياه ملوحتها 0.5 ديسمز/م في الفصل الثاني الى 9.46 ، 8 ، 7.53 ، 4.3 ديسمز/م للترب المزيجية الطينية والمزيجية والمزيجية الرملية والرملية المزيجية على التوالي.https://rengj.mosuljournals.com/article_47393_6e4c179f0aaa4e46bca0a0b892eb6248.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Tensile Stress-Strain Relationship For Ferro cement Structuresعلاقة اجهادالشد-الانفعال للمنشآت الفيروسمنتية27404727410.33899/rengj.2012.47274ENAzad A. MohammedDunyazad K. AssiJournal Article20120401Abstract
Tests on fibrocement discs were carried out to measure tensile stress- strain relationship including testing wide ranges of matrix strength. Equations were proposed for calculating tensile strength based on the present test results and other results in the literature. A trilinear idealized model was proposed for calculating tensile stress – strain response of Ferro cement. The model was found to be accurate especially for higher strength Ferro cement. Later an analysis was carried out for calculating the load-deflection relationship of Ferro cement beams based on moment – curvature relationship and bending theory of elastic beam. The analysis which based on the proposed tensile model was found to be accurate for Ferro cement beams and slab strips provided that the span / depth ratio less than 22.
KEYWARDS: Analysis, Beam, Elastic, Ferro cement, Flexure, Plastic, Slab, Strain, Tensile Stressالخلاصةفي البحث الحالي تم اجراء فحوصات لقياس علاقة اجهاد الشد – الانفعال على نماذج فيروسمنتية لانواع مونة السمنت بمقاومة انضغاط مختلفة .تم تطوير معادلات لحساب مقاومة الشد القصوى لفيروسمنت بالاستفادة من النتائج العملية للبحث الحالي ونتائج بحوث اخرى . نم اقتراح علاقة من نوع الخطي الثلاثى لحساب علاقة اجهاد الشد-الانفعال لفيروسمنت . وجدت بان الطريقة دقيقة لحساب علاقة اجهاد الشد-الانفعال خصوصا عندما تزداد مقاومة الانضغاط لمونة السمنت .بعدها تم تقديم طريقة التحليل غير الخطى لحساب علاقة الحمل – الاود للعارضات والبلاطات الفيروسمنتية بالاستفادة من اشتقاق علاقة العزم – التقوس للمقطع و نتائج الاود للصفائح المرنة .وقد وجدت بأن طريقة التحليل دقيقة لحساب علاقة الحمل- الاود وعلاقة العزم – التقوس للعارضات والبلاطات الفيروسمنتية عندما يكون نسبة الفضاء / عمق المقطع اقل من 22.https://rengj.mosuljournals.com/article_47274_ddb9b666d285aab880e5f57416d007ca.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Study of the Relationship between Organic Content Measures in Waterدراسة العلاقة بين مؤشرات التلوث العضوي في المياه33444739710.33899/rengj.2012.47397ENRiyadh MahmoodSaleh AL-ObaidiJournal Article20120401Abstract:
Organic content measures (COD, BOD, and TOC) has been tested for different types of waters, municipal wastewater, treatment plant influent and effluent, synthetic wastewater and river water samples. The correlation between each two parameters has been studied. The results revealed that the relationship between BOD and COD is not always invariant and its changing depending on the type and the state of the samples (raw, treated or ..etc.). TOC also had changing relationship with COD, however, the TOC,COD relationship was best than the BOD relationship with the other two parameters. The separation between the data and homogenizing them gave best correlation. Finally , equations describing the relation between the three parameters has been edited and they can be used to estimate the absent test in accepted accuracy in similar samples to which have been studied in this work. The equations represent Mosul city wastewater samples were: (BOD=0.461COD-23.46), (TOC=0.455COD+7.938), and (TOC=0.625BOD+24.87) with R2= 0.511, 0.824 and 0.648 respectively. More equations are included in this work.
Keywords; organic content, TOC, BOD, COD, Correlation , wastewater, characteristicsالملخصجرى في هذا البحث قياس أبرز المؤشرات العضوية (المتطلب الكيمياوي والحيوي للاوكسجين BOD,COD والكاربون العضوي الكلي TOC) لانواع مختلفة من المياه :مياه فضلات مدنية ومياه محطة معالجة فضلات ومياه فضلات مصطنعة مختبرياً فضلا عن عينات نهرية. وتمت دراسة علاقة الترابط بين تلك المؤشرات ، وقد لوحظ بأن العلاقة بين مؤشري BOD,COD ليست ثابتة وتتفاوت بتفاوت مصدر المياه وحالتها (خام، معالجة، او غيرها) ، مؤشر TOC بدوره تفاوتت علاقته مع COD ، ولكن ارتباطهما مع بعض كان أوثق من ارتباط كل منهما مع مؤشرBOD . أما عن علاقة TOC مع BOD فقد كانت ضعيفة نوعا ما في الفضلات المدنية لمدينة الموصل. وقد لوحظ ايضا بأن الفصل بين البيانات عن بعضها ومجانستها(حسب حالتها خام او معالجة) يحقق افضل ترابط مما لو دمجت كل البيانات في علاقة واحدة . وأخيرا فقد تم استنتاج المعادلات التي تربط كل مؤشرين على حدة وبما يمَكِّن من تخمين المؤشرات الغائبة في المياه المماثلة لتلك التي تمت دراستها بهذا العمل. فكانت لمياه الفضلات المدنية لمدينة الموصل ( BOD=0.461COD-23.46 )، و (TOC=0.455COD+7.938 ) و (TOC=0.625BOD+24.87) وبمعملات ارتباط R2 مساوية لـ 0.511 و0.824 و 0.648 على الترتيب. فضلا عن معادلات اخرى . الكلمات المفتاحية : المحتوى العضوي ، الكاربون العضوي الكلي، المتطلب الكيمياوي للاوكسجين ، المتطلب الحيوي للاوكسجين.https://rengj.mosuljournals.com/article_47397_3b990cf8418188d7cb605fa76136e58f.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428The Effect of Filler Types and Superplastizier on the Workability and Splitting Tensile Strength of Self-Compacting Concreteتأثير أنواع المواد المالئة والملدن الفائق على قابلية التشغيل ومقاومة الشد بالانشطار للخرسانة ذاتية الرص41544727710.33899/rengj.2012.47277ENRaid Ismaeel MohammedDr. Saeed K. RejebJournal Article20120401AbstraAbstract
Self-compacting concrete (SCC) is a special type of concrete that can flow through intricate geometrical configurations under its own mass without external or internal vibration or segregation. The objectives of the research work were to evaluate the effects of filler types (silica fume and limestone dust) and high- range water- reducing agent, (HRWRA, superplastizier-type Sikament -163) on the workability and splitting tensile strength of SCC. The experimental results showed the using silica fume and limestone dust in Self-compacting concrete led to a considerable improvement in splitting tensile strength. As the percentage of limestone powder and silica fume increases, the workability properties of SCC slightly decreased with increases in splitting tensile strength. The workability properties of SCC for all the replacements satisfy the recommended values given by specifications.
Keywords: self-compacting concrete, silica fume, limestone dust, fillers, strengths, splitting, super plasticizersقسم التقنيات المدنية، المعهد التقني - الموصلالخلاصةالخرسانة الذاتية الرص هي نوع جديد من الخرسانة والتي يمكن ان تنساب خلال المقاطع الخرسانية المعقدة بتاثير وزنها دون الحاجة الى رصها بالاهتزاز وبدون حصول انعزال في مكوناتها. الغايات من مشروع البحث هذا هي لبيان تاثيرات أنوع المواد المالئة (غبار السيليكا ومسحوق الحجر الجيري) مع الملدن الفائق نوع (Sikament-163) على قابلية تشغيل ومقاومة الشد الانشطاري للخرسانة الذاتية الرص. تبين النتائج التجريبية, بان استخدام غبار السيليكا ومسحوق الحجر الجيري في الخرسانة الذاتية الرص ادى الى تحسن مميز في مقاومة الشد الانشطاري. عند زيادة نسبة مسحوق الحجر الجيري و غبار السليكا فان قابلية التشغيل للخرسانة الذاتية الرص قلت قليلا ولكن مقاومة الشد الانشطاري ازدادت. خواص قابلية التشغيل للخرسانة الذاتية الرص لجميع نسب الاستبدال كانت مرضية وضمن القيم المعطاة في المواصفات.https://rengj.mosuljournals.com/article_47277_a4f64380c8775f942707bd6521dc06ab.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Water Reclamation of Kharazi Wadi for Irrigationتعديل خصائص ماء مجرى الخرازي لاستخدامات الري45604739910.33899/rengj.2012.47399ENMohammed Sulaiman HassanMazin Siddek AlyasJournal Article20120401In the present research Thirty raw water samples were collected from kharazi wadi for further treatment , Those samples represent a mixture of (municipal ,irrigation and storm) sewage discharged directly to Tigris river north Mosul city .The Jar test technique was conducted to measure the variation of the main important characteristics of irrigation water . The treatment was carried out using bentonite clay as a coagulant compared with the treatment by sedimentation only. The results showed that the bentonite clay was more effective in removing :BOD, EC, TSS, Coliform bacteria and phytoplanktonic algae and max% removal recorded were (%51.43,%14.54) (%1.43,%0.95) (%72.22,%68.52) (%70.45,%47.20) (%53.33,%14.70) respectively ,The result indicated also that the reclamation of Kharazi Wady sewage was according to WHO standard for irrigation pwposes.الخلاصةتم في هذا البحث معالجة(30) نموذجا من مياه مجرى الخرازي وهي مزيج من مياه الفضلات المنزلية والزراعية ومياه السيول وتصرف حاليا إلى نهر دجلة شمال مدينة الموصل, تمت المعالجة بالترسيب فقط وباستخدام طين البنتونايت كمخثر مع الترسيب باعتماد فحص الجرة كنموذج مختبري لمتابعة التعديلات الحاصلة على الخصائص المهمة لاستخدامات الري. وقد حققت المعالجة بالترسيب فقط وباستخدام طين البنتونايت مع الترسيب أعلى نسب إزالة لخصائص:- الأوكسجين الحيوي (%51.43,%14.54) والتوصيل الكهربائي (%1.43,%0.95) والمواد الصلبة الكلية العالقة (72.22,%68.52%) ، وبكتريا القولون (%70.45,%47.2)والهائمات الطحلبية (%53.33 %14.7) على التوالي بحيث أصبح الماء المستصلح مناسبا لسقي الأشجار والمحاصيل العلفية حسب محددات منظمة الصحة العالمية WHO.الكلمات الدالة :- طين البنتونايت ,استصلاح المياه ,إعادة استخدام المياه , مجرى الخرازيhttps://rengj.mosuljournals.com/article_47399_c6db0f4246c33178ed5e8a2efce32ded.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Experimental Study on theBehaviour of High StrengthConcrete with Silica Fume under Monotonic and Repeated Compressive Loads دراسة عملية لسلوكية الخرسانةعالية المقاومة الحاوية على مادة غبار السليكا تحت تأثير الاحمال التزايدية والتكرارية الانضغاطية55654727810.33899/rengj.2012.47278ENJournal Article20120401Abstract
The main objective of this paper is to determine the effect of silica fume on the compressive strength of concrete under two types of loading, monotonic and repeated compressive loads. Mixes were carried out by replacing cement with different percentages of silica fume of (0, 5,10,15,20) % by wt. of cement with a constant water-binder ratios 0.25. Tests on standard cylinders (300*150) mm for the different ratios of silica fume were carried out to study the behavior of concrete under monotonic and repeated loads, the load was applied for many cycles up to failure with rate of loading (0.3) N/mm2/sec. The results indicated that the addition of silica fume improves the properties of concrete giving high compressive strength, high stress and strain, stresses carried by the concrete increased by (46.3,68.8,63.1,57.5)% also the strain increased by (58.5,97.8,52.8,22)% for silica fume percentages (5,10,15,20)% for monotonic loading, and stresses increased by (44.4,68.5,63.7,56.5)% and strain increased by (45.8,68.4,51.5,26.3)% for the same percentages under repeated loads. Compressive strength, dissipated energy, and modulus of elasticity also increased with increasing silica fume percentage.
KeyWords: Silica fume, High Strength Concrete, Stress, Strain, Repeated and Monotonic Loads.الخلاصةإن الهدف الأساسي من هذا البحث هو دراسة تأثير اضافة مادة غبار السليكا على مقاومة الانضغاط للخرسانة تحت تأثير نوعين من الاحمال, احمال تزايدية واحمال تكرارية. اذ تم اسـتخدام مادة غبار السليكا بنسب ( 0و5و10و15و20 )% من وزن الاسمنت وكانت نسبة الماء الى المادة الرابطة (0.25). تضمن البحث فحوصات عملية على نماذج اسطوانية خرسانية قياسية بأبعاد(300*150) ملم تحتوي على النسب الوزنية المختلفة لغبار السليكا ولكل نسبة من هذه النسب تم صب ثلاث اسطوانات وإيجاد المعدل لها وذلك لدراسة سلوك الخرسانة الحاوية على هذا النوع من المواد تحت تأثير الأحمال التزايدية والتكرارية. تم تسليط الاحمال الدورية لعدة دورات لغاية الفشل وبنسبة تحميل (0,3)نيوتن/ملم2/ثا. ومن خلال النتائج التي تم الحصول عليها اثناء الفحص لوحظ ان اضافة مادة غبار السليكا ادى الى تحسين خواص الخرسانة من حيث مقاومة الانضغاط وايضا الاجهاد و الانفعال, أذ يلاحظ من النتائج أن الاجهادات التي تتحملها الخرسانة قد زاد بنسبة (57.5,63.1,68.8,46.3) كما ازداد الانفعال بنسبة (22,52.8,97.8,58.5) % لنسب غبار السليكا (20,15,10,5)% بالنسبة للاحمال التزايدية, وازدادت الاجهادات بنسبة (56.5,63.7,68.5,44.4) % والانفعال بنسبة (26.3,51.5,68.4,45.8) % لنفس نسب غبار السليكا تحت تأثير الاحمال التكرارية. كما بينت النتائج ازدياد كل من مقاومة الانضغاط ومعامل المرونة والطاقة المتبددة بزيادة نسبة غبار السليكا.https://rengj.mosuljournals.com/article_47278_5efd27bd5fd9efc3cb84aad4eb9ea86d.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Compressive and Tensile Strength of Fibrous Clayey Soil Stabilized with Limeمقاومة الانضغاط والشد للتربة الطينية الحاوية على الألياف والمثبتة بالنورة66774728010.33899/rengj.2012.47280ENI. M. Al-KikiA. H. Al-ZubaydiM. A. Al-AtallaJournal Article20120401Abstract
This investigation was conducted to assess the efficacy of the glass, hay and polypropylene fibers for enhancing the unconfined compressive and tensile strengths of clayey soil stabilized with lime. Lime was mixed with the clayey soil in different proportions. Based on the optimum value obtained for lime (according to the unconfined compressive strength values), the compressive and tensile strength characteristics, stress – strain and load – deflection behaviors of lime stabilized samples mixed with different percents of glass, hay and polypropylene fibers were investigated. Fibers were added to the soil at range of (0.5 – 1.5 %). All stabilized samples were cured for 7 days at 250 C.
Results indicate that the inclusion of fibers does not meaningfully improve the compressive strength, but significantly enhances the tensile strength, stress – strain and load – deflection behaviors. Also, it was found that the stress – strain and load deflection curves can be utilized to evaluate the performance of a fiber – reinforced stabilized soil for geotechnical and pavement applications.
Keywords: Lime stabilization, fibers, tensile strength, stress – strain behavior, load – deflection behavior.الخلاصةيهدف هذا البحث إلى دراسة تأثير إضافة كل من الألياف الزجاجية وألياف التبن والبولي بروبلين على خصائص مقاومة الانضغاط والشد للتربة الطينية المثبتة بالنورة. تم إضافة نسب مختلفة من النورة إلى التربة وتم ايجاد نسبة النورة المثلى بالاعتماد على نتائج فحص الانضغاط غير المحصور. تم إضافة نسب مختلفة من ألياف الزجاج, التبن والبولي بروبلين إلى نماذج التربة المثبتة بنسبة النورة المثلى, اذ تراوحت هذه النسب بين (0.5 – 1.5%) وتم إنضاج النماذج المثبتة لمدة 7 أيام بدرجة حرارة 25 درجة مئوية. بعدها تم إيجاد خصائص مقاومة الانضغاط والشد, كذلك تم ايجاد كل من منحنيات الإجهاد – الانفعال ومنحنيات الحمل – الأود.أظهرت النتائج حصول زيادة في كل من مقاومة الانضغاط ومقاومة الشد, وكان مقدار التحسن في مقاومة الشد أكثر منه في مقاومة الانضغاط لنماذج التربة المضاف إليها الألياف. أيضا بينت النتائج أنه يمكن الاستفادة من منحنيات الإجهاد – الانفعال ومنحنيات الحمل – الأود في تقييم أداء الطرق المثبتة والمضاف إليها الألياف.https://rengj.mosuljournals.com/article_47280_a138f43357d5cce933250246d949151a.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Warm Forming of Aluminum Alloy 2024 at Different Temperaturesالتشكيل الدافئ لسبيكة الألمنيوم (2024) عند درجات حرارة مختلفة78854728310.33899/rengj.2012.47283ENO. Th. JumahW. J. AliJournal Article20120401Abstract
Forming of aluminum sheets at warm forming temperatures has been investigated as an alternative manufacturing process for improving formability compared with forming at room temperature. However, the forming technology should be developed to increase the application field, especially in the predication of formability and the failure in order to design the process and die outcomes. The results obtained during this study showed that the formability of annealed Al-alloy (Al-2024-O) is increased by increasing temperature. Its formability is significantly improved compared with the precipitation hardened alloy (Al-2024-T3). The possibility of forming (Al-2024-T3) sheet metal at moderate temperatures, with acceptable formability and higher strength for structural parts is much better if compared to the annealed condition (Al-2024-O).
Key words : warm forming, formability, aluminum alloy (2024)الخلاصةتم دراسة تشكيل صفائح الألمنيوم عند درجات حرارة التشكيل الدافئ كطريقة بديلة في التصنيع من اجل تحسين قابلية التشكيل مقارنة بالتشكيل عند درجة حرارة الغرفة. على أية حال فان تكنولوجيا التشكيل يجب إن تطور لزيادة تطبيقها وخصوصا في التنبؤ بقابلية التشكيل والفشل من اجل تصميم عملية التشكيل والمعدات الخاصة بها. أظهرت النتائج خلال هذه الدراسة بان قابلية التشكيل لسبيكة الألمنيوم (AL-2024-O) في ظرف التلدين التام تزداد بازدياد درجة الحرارة وإنها تظهر تحسن واضح مقارنة بسبيكة الألمنيوم (Al-2024-T3) المصلدة بالترسيب. إن إمكانية تشكيل سبيكة الألمنيوم (Al-2024-T3) عند درجة حرارة متوسطة مع قابلية تشكيل مقبولة ومقاومة شد أعلى لأجزاء الهياكل يعتبر أفضل مقارنة بنفس السبيكة في ظرف التلدين التام.https://rengj.mosuljournals.com/article_47283_632049786393a574ed00ff7eba806e45.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Numerical Investigation of Natural Convection Heat Transfer in Porous Medium Saturated With Carbon Dioxide in Supercritical Stateدراسة عددية لانتقال الحرارة بالحمل الطبيعي في تجويف مربع مملوء بوسط مسامي مشبع بثنائي اوكسيد الكاربون في الحالة الفوق الحرجة86974728610.33899/rengj.2012.47286ENDr. Amir S. DawoodYounis M. NajimMohanad K. RadhiJournal Article20120401Abstract
Natural convection in a porous medium saturated with supercritical carbon dioxide (CO2) whichis bounded by square cavity is studied numerically by solving the governing Darcy equation using finite-differences method.The side walls of cavity were assumed to be isotherm with fixed temperature difference of 0.0152K, while the upper and lower sides are assumed to be thermally insulated, the aspect ratio is chosen to be one, with cavity height of 0.01 m, the Darcy number adopted is , usually these values lead to very small modified Rayleigh number. Despite all of this, the state of supercritical takes the fluid (CO2) to a huge changes in its properties ( ) which allow to transfer a relatively large amount of heat between the hot and cold sides of the cavity with a very small temperature difference with maximum Nusselt number over 13 . The results of this study show clearly these concepts. The state of carbon dioxide in supercritical region is specified by reduced pressure and reduced temperature , the reduced temperature and pressure have been varied as .
Keyword: Natural convection, porous media, supercritical carbon dioxideالخلاصةتناولت هذه الدراسة التحليل العددي بطريقة الفروق المحددة لانتقال الحرارة بالحمل الطبيعي داخل تجويف مربع الشكل ومملوء بوسط مسامي مشبع بـثنائي اوكسيد الكاربون عندما يكون في الحالة فوق الحرجة, واعتبرت جدران التجويف العلوي والسفلي معزولة حرارياً, اما الجانب الايسر للتجويف فسخن بدرجة حرارة ثابتة وتزيد عن درجة حرارة الجدار الايمن بـ K 0.0152 , اما ارتفاع التجويف فكان يساوي m0.01 اما عدد دارسي ففرض انه يساوي ومن المعلوم ان هذه القيم الصغيرة نسبيا ينتج عنها عدد رالي المعدل بقيمة صغيرة جدا لايمكن من خلالها تحريك ثنائي اوكسيد الكاربون داخل الوسط المسامي نحو الحمل الطبيعي, الا ان وجود ثنائي اوكسيد الكاربون بالحالة فوق الحرجة فان النتائج اظهرت تغيرا جذريا عن مفاهيم انتقال الحرارة بالحمل الطبيعي في الحالة الاعتيادية لثنائي اوكسيد الكاربون فقد ادت التغيرات الكبيرة للخواص الحرارية والفيزيائية( ) لثنائي اوكسيد الكاربون الى ارتفاع كبير وتحول في عدد رالي المعدل مما ادى الى انتقال كبير للحرارة بين الجدارين الايسر (الساخن) و الايمن (البارد) وبعدد نسلت وصل الى 13.56, شملت الدراسة عدد من قيم الضغط ودرجة الحرارة في الحالة الفوق الحرجة من خلال استخدام الضغط ودرجة الحرارة المنقصين حيث و , وتم تغييرهما للفترة:https://rengj.mosuljournals.com/article_47286_d9a8e19694cd0d0ac85802be3cae3523.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Tensile Strength Determination of heat Treated Austenitic Stainless Steel AISI 316L Using (ABI) Method ايجاد مقاومة الشد القصوي للصلب المقاوم للصدأ اللاوستنايتي AISI 316L المعامل حراريا وذلك باستخدام تقنية (ABI)981054728710.33899/rengj.2012.47287ENRamadhan H. GardiJournal Article20120401Abstract
In this study, austenitic stainless steel AISI 316L has been selected to investigate the effect of aging time and temperature on tensile strength using (ABI) technique. Heat treatment consisted of aging at temperature of 400 oC, 600 oC and 800 oC and socking time for 0.5, 1.5, 10, 24 and 72 hrs.For microstructure examination, an optical microscope were used. The results showed that with increasing the aging time at 400 oC and 600 oC the tensile strength will increase but this approach inverted at 800 oC. These results could be attributed to some metallurgical transformation that occurs during heat treatment like changing in grain size, carbide and nitride precipitation along the grain boundaries, and secondary austenite.
KEY WORDS: Tensile strength, 316L, austenitic stainless steel, ABI, heat treatmentالخلاصةفي هذه الدراسة استخدمت سبيكة الصلب المقاوم للصدا الآستنايتى AISI 316L لتحديد تاثير التغيرات الميتالورجية التى تحصل نتيجة المعاملات الحرارية علي مقاومة الشد القصوي وذلك باستخدام تقنية (ABI) (Automated Ball Indentation). المعاملة الحرارية تتكون من التعتيق في ثلاث درجات الحرارية المختلفة (400 oC,600 oC,800 oC )و لخمسة فترات زمنية مختلفة (0.5,1.5,10,24,72)ساعة لكل درجة.اضهرت النتائج بان زيادة زمن التعتيق من oC 400 و 600 oC ان مقاومة القصوي تزداد و لكن المادة تتصرف عكس ذلك في درجة الحرارة 800 oCوان اسباب هدة النتائج تعود بشكل اساسي الي التغيرات الميتالورجية في الصلب اللاوستنايتي ومن بين هدة التغيرات التحولات الطورية,تغير حجم البلورات ،ترسيب كاربيدات ونتريدات علي حدود البلورات،.......الخالكلمات الدالة:مقاومة الشد،الصلب الاوستنايتيكى،ABI،المعاملة الحراريةhttps://rengj.mosuljournals.com/article_47287_88246b1689ccb7e67810ec11b014f685.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Friction and indicated power measurement for diesel engine by ( aerial dynamometer قياس القدرة الأحتكاكية والبيانية لمحرك ديزل بواسطة (الداينموميتر الهوائي)1061154728810.33899/rengj.2012.47288ENMohammad Sami AhmadJournal Article20120401Abstract:
The conventional methods - used for - measuring brake, friction, and indicated power are based on brake - off dynamometers which use hydraulic or electrical dynamometers .
The mentioned above methods use the measured torque to calculate the related power.
The present method and instrument are characterized by measuring the amount of pressure opposed by a compressor joined to the engine and a reservoir for a compressed air, thus; the engine speed decelerates with the increasing pressure . For a specified pressure and engine speed, power could be calculated.
In addition, friction power in the engine could be estimated by measuring the consumed current and effective voltage on an electrical driving motor when the diesel engine at run – off situation; no fuel supply. The whole present dynamometer had been designed and performed by the researcher as explained.ان النظريات التقليدية المستخدمة في قياس القدرة الفرملية والاحتكاكية و البيانية للمحركات اعتمدت على داينموميتر التوقف الهيدروليكي أو الكهربائي . وهذه الطرق تستخدم العزم المضاد و المقاس لحساب القدرة المعنية بتلك المحركات. أما الطريقة الحالية فقد تميزت بقياس مقدار الضغط المسلط بواسطة ضاغط هواء مرتبط بالمحرك بواسطة محور دوراني مع وجود خزان ضغط لإبقاء الحمل المسلط في حالة اتزان طيلة فترة الأختبار. وعليه فإن سرعة المحرك ستتناقص مع تزايد الضغط . وعند سرعة معينة وضغط معين يمكن حساب القدرة المطلوبة. بالإضافة لذلك ، يمكن تقدير القدرة الاحتكاكية داخل المحرك بقياس التيار المستهلك والفولتية المسلطة على المحرك الكهربائي المستخدم في تدوير محرك الديزل في حين أن محرك الديزل في حالة عدم اشتغال .ان الداينموميتر المستخدم مصمم ومنفذ بشكل كامل من قبل الباحث كما موضح من خلال البحث الحالي.https://rengj.mosuljournals.com/article_47288_7f9d89304d2271fac637d98297861c0f.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Modelingand AnalysisofIXP425 Network Processorنمذجة وتحليل اداء معالج الشبكاتIXP4251161304728910.33899/rengj.2012.47289ENFakhraldeen HAli Omar F. AhmedJournal Article20120401Abstract
There are mainly two kinds of network processor: coprocessors-centric model, and core-centric model. In the coprocessors-centric, the data-plane is handled by coprocessors. The core processes most of the data-plane packets yet offloading some tasks to coprocessors in the core-centric model. The IXP is one of Intel network processor series which is a core-centric model. They are optimized for home, small-to-medium enterprise, and networked embedded applications.This work aims to design a module of IXP425 performing VPN. The processing time for each stage is available in the datasheet of the IXP425. The Markov chain and Omnet++ has been adopted in this work to explore the system parameters and bottlenecks focusing on the buffer length and how to be optimized for each stage. Single process programming is considered in the IXP425 operation.
Keywords:VPN, network processor, configurability, flexibility, scalability.الخلاصةهنالك نوعان رئيسيان من معالجات الشبكات الاختلاف الجوهري بينهما ينصب حول كيفية المعالجة على مستوى البيانات حيث اما يتم ذلك من قبل المعالج المركزي او من قبل المعالجات المساعدة. يركز هذا البحث على معالج شبكات انتجته شركة انتل حيث تم نمذجة هذا المعالج واعتماد الازمنة المتوفرة في المواصفات الفنية له لاجراء محاكات لقياس ادائه وتأشير الاختناق أو عنق الزجاجة مع التركيز على دوائر العزل والجم الأفضل لكل مرحلةوصولا إلىأفضل أداء عندتبني Markov chain و Omnet++ .https://rengj.mosuljournals.com/article_47289_a1831fc45ef154069614d3b8042f2705.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Transmission Spectrum Shifting By Varying Ambient Refractive Index in LPFGإزاحة طیف الإرسال بتغییر معامل انکسار المحیط الخارجی فی المحزز اللیفی ذو الفترة الطویلة1311394729010.33899/rengj.2012.47290ENFurat.y. Abdul-RazakJournal Article20120401ABSTRACT<br /> <br /> In this paper,we introduce a new model, of long-period fiber grating, by taking the value of ambient refractive index greater than the refractive cladding index, where the difference between them must equal(≈0.2).The results show the change in power attenuation coefficient, where it increases with the increase in refractive ambient index. The power attenuation coefficient shift shows a dramatic change of a sharp increase from 0.00dB to ≈ 0.03788dB and 0.00dB to ≈ 0.04675dB and 0.00dB to ≈ 0.06875 dB. Here this model is used as sensor for shifting in input signal (15nm, 5nm). <br /> <br /> Key Word: Long Period Fiber Grating, single mode fiber opticalالخلاصـة فی هذا البحث قدمنا نموذجآ جدیدآ من المحزز اللیفی ذو الفترة الطویلة, من خلال اخذ قیمة معامل الانکسار للمحیط الخارجی اکبر من معامل الانکسار لقشرة المحزز اللیفی ذو الفترة الطویلة, بحیث یکون الفرق بینهما یساوی (0.2≈). بینت النتائج التغیر الحاصل فی معامل توهین القدرة، حیث إن معامل التوهین یزداد مع الزیادة فی معامل الانکسار للمحیط الخارجی التی تکون أعلى من معامل الانکسار للقشرة ولکن ضمن مدى معین یتناسب مع معامل الانکسار لقشرة المحزز ( یزداد من dB0.00 إلى≈ dB 0.03788و0.00dB إلى≈ 0.04675dB و 0.00dB إلى≈ 0.06875dB). لقد تم استخدام هذا النموذج کمتحسس للازاحة فی أشارة الإدخال 5nm) .(15nm,https://rengj.mosuljournals.com/article_47290_c54ee41e1117ab2c474082365f02b491.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428A SimpleMethod to Derive the Bistatic Tracking Radar System Formulasطريقة بسيطة لأشتقاق معادلات رادار التتبع الثنائي1401494729110.33899/rengj.2012.47291ENKhalil Ibrahim Ali Al-SharabiJournal Article20120401Abstract
BistaticTracking Radar (BTR) is an advanced mode of conventional BistaticRadar (BR) which is used for target detection. The principle of working of BTR system is same as that for Mono Static Tracking Radar (MTR), with the difference that the transmitter is apart from the receiver,and they operate separately and independently. In this paper,the associated equations that control the BTR system operation, was derived in a simple manner. These equations determine the receiver and transmitter antenna positions to keep their lines of sight meet at the target, beside the assurance of tracking the target during maneuvering. The operation of the system was explained and the simulation program was made to characterize the operation of the system by using the derived equations in this paper.
Keywords: Bistatic Radar, Tracking, Radarالخلاصةان رادار التتبع الثنائي هو نموذج متقدم من الرادار الثنائي الاعتيادى الذى يستخدم لكشف الاهداف الجوية. ان طريقة عمل هذا الرادار تشبه من حيث المبدأ طريقة عمل رادار التتبع الاحادى الحالة مع ملاحظة ان المرسلة تكون بعيدة عن المستقبلة وتعملان بشكل منفصل عن بعضهما فى رادار التتبع الثنائي. لقد تم فى هذا البحث اشتقاق المعادلات الخاصة برادار التتبع الثنائي للتوفيق بين مواقع الهوائيات للمرسلة والمستقبلة بحيث تلتقى خطوط الاشعة لهذه الهوائيات عند الهدف مع ضمان استمرارالمتابعة للهدف اثناء المناورة.تم توضيح عمل هذا النظام واعداد برنامج تشبيهى لتمثيل عمل النظام باستخدام المعادلات التى تم التوصل اليها فى هذا البحث .https://rengj.mosuljournals.com/article_47291_e967f04b7e3d3477f15649cbbe50a98c.pdfCollege of Engineering, University of Mosul, IRAQAl-Rafidain Engineering Journal (AREJ)1813-052620220120428Refine Priority Queuing Scheduling Algorithm By Applying Time Expired Packets Algorithmتحسین أداء خوارزمیة الجدولة حسب الأسبقیة عن طریق تطبیق خوارزمیة إهمال الحزم المنتهیة الصلاحیة1501634738310.33899/rengj.2012.47383ENDr.Mohammed B. AbdullahYazen S.SheetJournal Article20120401Abstract<br /> Quality of service (QoS) is a corner stone in recent Internet applications. One of the requirements of achieving QoS in routers is scheduling algorithms. Priority Queuing (PQ) is the simplest most used scheduling algorithm. This algorithm may cause starvation in less priority queues. Time Expired (TE) algorithm is a refine of PQ which discards packets that would reach the receiver out of time. Thus improving throughput and delay for less priority queues with the discard of retarded usefulpackets in time sensitive – loss tolerant Internet applications. A simulation study using OPNET Modeler is carried out. The results show a 20% improvement in throughput of less priority applications. The delay performance is improved for all applications by a factor of 4% to 42% <br /> <br /> Keywords: QoS, Scheduling Algorithms, Priority Queuing Algorithm,OPNETالخلاصةتعتبر جودة الخدمة حجر الزاویة فی التطبیقات الحالیة لشبکة الانترنیت. ومن متطلبات تحقیق جودة الخدمة تطبیق خوارزمیات الجدولة فی الموجهات. من أسهل هذه الخوارزمیات وأکثرها استخداما خوارزمیة الجدولة حسب الأسبقیة ولکن قد یسبب تطبیق هذه الخوارزمیة انحسارا فی خدمة التطبیقات ذات الأسبقیات الاوطأ. اقترحت خوارزمیة انتهاء الصلاحیة لغرض التقلیل من مساوئ خوارزمیة الجدولة حسب الأسبقیة على خدمة التطبیقات ذات الأسبقیات الاوطأ حیث تقوم الخوارزمیة المقترحة بإهمال الحزم التی یتطلب وصولها إلى المستلم وقتا یتجاوز الوقت الذی تکون فیه مفیدة. وبهذا تم تحسین معدل الاستلام وزمن التأخیر لبقیة التطبیقات من خلال إهمال هذه الحزم المتأخرة من التطبیقات(الحساسة للزمن والقابلة للفقد) والتی یعتبر إرسالها غیر مجدی عبر الشبکة. تمت محاکاة عمل الخوارزمیتین باستخدام برنامج (OPNET Modeler) ولوحظ من خلال النتائج أن هناک تحسن فی معدل الاستلام لبقیة التطبیقات بمقدار 20% فی حین أن زمن التأخیر قد تحسن لجمیع التطبیقات بنسبة 4% إلى 42%https://rengj.mosuljournals.com/article_47383_5d7fccfb46982123f399d9462508e518.pdf